RATED VOLTAGE | 250 vac | ||
RATED CURRENT | 10a | ||
OPERATIONAL FR. | 50 or 60 Hz | ||
TEST VOLTAGE | 2250VDC line-ground 1500VDC line-line |
IN/OUT CONNECTOR | soldering lug | ||
INSULATION RESISTANCE | 2000M ohm | ||
CLIMATIC CATEGORY | 25/085/41 |
Attribute | Value |
Maximum Current Rating | 10A |
Maximum Voltage Rating | 250 V ac |
Mounting Type | Chassis Mount |
Termination Style | Tab |
Number of Stages | Single Stage |
Series | TFNF |
Operating Frequency | 400Hz |
Length | 90mm |
Depth | 52mm |
Height | 40mm |
Capacitance | 0.47 x 2 μF, 22 x 2 pF |
Dimensions | 90 x 52 x 40mm |
Inductance | 5 x 2 mH |
Leakage Current | 2.1 mA |
Minimum Operating Temperature | -25°C |
Maximum Operating Temperature | +85°C |
Resistance | 220kΩ |
Features:
-- Designed 2 stage enhanced filtering to prevent the power supply may produce interference to the device;
-- Various terminal options allow you to select;
-- There are a variety of parts and combinations to meet different customer's EMC tests.
Typical Applications:
1. Electrical and electronic equipment
2. Medical equipment
3. Building automation
4. Office automation equipment